NHA CET · free practice questions · 2017 plan weights
Free NHA EKG practice test for the CET exam
This NHA EKG practice test has 30 questions, mixed the way the current test plan mixes the Certified EKG Technician exam: acquisition questions are the largest group, then safety and patient care, then analysis. Pick an answer to see a note under each choice. There is no timer and no sign-up. Each card has four choices and a label naming its domain. Rhythm questions state the rate, intervals and complex width in words, because the set has no strip images.
On the exam, EKG Acquisition accounts for 44 of the 100 scored questions, Safety, Compliance, and Coordinated Patient Care for 32, and EKG Analysis and Interpretation for 24. The cards follow that order of size.
Acquisition cards cover Holter hookups, chest landmarks, telemetry around a pacemaker, skin preparation, recording and coaching during a treadmill test, paper care, and sending the tracing to the chart. The patient care cards come from the stress lab, the telemetry station and the front desk: drug and nuclear stress tests, a patient overwhelmed by the room, documenting a test that ended early, and requests for records. Analysis cards work from measured spans and described rhythms: intervals, rate, AV conduction, ST changes and findings on a baseline tracing.
Taken fromCET test plan 2017 1CET news 2026 2CET test plan 2026 3
Rhythms without strips: how each card describes a tracing
A rhythm picture teaches something only when it is drawn to scale on a true grid, so this set does not show strips at all. Each rhythm card gives the measurements a strip would show you: the rate per minute, whether the beats are regular, whether P waves are there, and spans counted in small boxes or seconds.
Reading a printed strip by eye is a separate skill, best practiced on real tracings from your course or textbook. The box arithmetic behind these cards is in the analysis section of the study guide.
30 questions on the 2017 NHA plan
Answered 0 of 30 · right 0
Acquisition · 44%1 of 30—
During a treadmill test, when is a full 12-lead tracing typically recorded?
Pick a letter to lock it in; then each option shows its own reasoning.
ABefore exercise and in recovery, not during it
A goes wrong here. Skipping tracings during exercise would miss ST changes that appear only under load, which is the point of the test.
BAt the very start of each new stage
B goes wrong here. The start of a stage is when the heart rate is still adjusting to the new load; the tracing is taken late in the stage instead.
CNear the end of each stage and at peak exercise
C is the keyed choice. A full 12-lead is usually taken in the last part of every stage and at peak, plus at rest and during recovery.
DOnce, at the halfway point of the test
D goes wrong here. One tracing at the halfway point cannot show how the EKG changes from stage to stage or at peak.
An adult patient with autism becomes distressed by the bright lights and noise in the EKG room. Her caregiver is present. Which approach is MOST appropriate?
AAsk the caregiver to hold her still during the test
A goes wrong here. The caregiver can comfort and coach her, but holding her still is a restraint and would raise her distress.
BRecord quickly before she can become more upset
B goes wrong here. Recording quickly adds to the overload and tends to give a noisy tracing; a calm, explained test is faster in the end.
CPostpone the EKG and send her home to relax
C goes wrong here. The test was ordered and can be done here once the room is adjusted; sending her home delays care without need.
DLower the stimulation while explaining each step
D is the keyed choice. Cutting the light and noise removes what is upsetting her, and saying each step before it happens keeps the test predictable.
A patient with crushing chest pain is on the EKG machine, the screen shows new ST-segment elevation, and the thermal printer suddenly jams. What should the technician do first?
ARun a full recalibration per the manufacturer's guide
A goes wrong here. Recalibrating the system does nothing about a paper jam and spends the minutes this patient cannot spare.
BFix the printer first, then notify the physician
B goes wrong here. A printer can wait; ST elevation with ongoing chest pain cannot, so the physician comes before any repair.
CDisconnect and move the patient to a machine in another unit
C goes wrong here. Unhooking and moving an unstable patient delays the urgent finding and can lose the tracing on the screen.
DAlert the provider to the findings, then log the jam
D is the keyed choice. A patient with chest pain and ST elevation on the screen needs the provider at once; the printer is logged and fixed after that.
A patient scheduled for a one-day nuclear stress test asks how long to plan to be at the clinic. Which explanation by the EKG technician is correct?
AUnder 15 minutes, just like a routine resting EKG
A goes wrong here. Under 15 minutes fits a routine resting EKG, but a nuclear study adds tracer uptake times and imaging.
BAbout 30 minutes, with one set of images
B goes wrong here. One set of images in 30 minutes cannot compare blood flow at rest and under stress, which is what the test is for.
CSeveral hours, with two imaging sessions
C is the keyed choice. Several hours is realistic: a one-day study has a rest dose and imaging session, the stress portion and a second imaging session, with waits between them.
DRoughly an hour, with images during exercise only
D goes wrong here. Images are not taken during exercise; the camera scans after each tracer dose with the patient lying still, and an hour is far too short.
During a treadmill stress test, the patient asks to stop because of severe cramping in both calves. The EKG shows no ischemic changes. Which note best documents why the test ended?
ATest stopped for claudication from peripheral artery disease; provider notified
A goes wrong here. Peripheral artery disease is a diagnosis the technician cannot make; the chart should carry the reported symptom, not a guessed cause.
BTest stopped at patient request for calf cramping; provider notified
B is the keyed choice. The note states what happened and why in the patient's own terms, with the notification, and leaves any diagnosis to the provider.
CTest stopped as calf cramps showed poor fitness; provider notified
C goes wrong here. Blaming the cramps on poor fitness is the technician's opinion, not what the patient reported, and opinions do not belong in the note.
DTest stopped for a suspected DVT in the lower legs; provider notified
D goes wrong here. A suspected DVT is a diagnosis the technician cannot make; what the patient reported, a calf cramp, is what goes in the note.
A monitor technician watching the telemetry central station needs to step away for a few minutes. What must happen first?
ALeave it running and rely on the alarms
A goes wrong here. Alarms can be missed or set wrong, and someone must be there to read the rhythm and respond; an unattended station is unsafe.
BHand off to another qualified colleague
B is the keyed choice. A qualified colleague who can read rhythms must take over the central station before the technician steps away; it is never left unwatched.
CAsk the unit clerk to glance at it
C goes wrong here. A clerk is not trained to recognize rhythms, so a glance from an untrained person is not a real handoff.
DSilence the alarms until returning
D goes wrong here. Silencing the alarms removes the one safeguard left, so a lethal rhythm would go unnoticed.
Midway through chest electrode placement, a patient becomes irritated, removes the leads, and walks out of the clinic against medical advice. What should the technician do about the test record?
AFollow the patient outside and finish the chest leads
A goes wrong here. An adult has the right to leave; following the patient outside to finish the chest leads ignores that choice and does nothing for the record.
BSend the partial tracing to the provider as the final EKG
B goes wrong here. A partial tracing with chest leads missing is not a complete 12-lead; sending it as the final EKG invites a wrong reading.
CMark the test incomplete and inform the provider
C is the keyed choice. Marking the test incomplete shows that no full tracing was made, and informing the provider lets follow-up be arranged.
DDelete the unfinished record from the cart
D goes wrong here. Deleting the entry hides that the test was started and stopped, which the chart must show.
A patient scheduled for a treadmill stress test weighs 420 lb (191 kg), and the treadmill's label lists a maximum user weight of 350 lb (159 kg). What should the technician do?
AHold the test and report the rated limit to the provider
A is the keyed choice. Running a treadmill above its rated weight risks a belt or frame failure and a fall, so the provider decides on another way to stress the heart.
BRun the test at a slower belt speed and lower grade
B goes wrong here. Belt speed and grade do not change how much weight the deck and motor carry; the limit still applies.
CProceed as ordered, with the provider in the room
C goes wrong here. Proceeding with the provider in the room does not make an overloaded machine safe; the rated maximum is still exceeded.
DHave the patient lean on the rails to unload the belt
D goes wrong here. The rails are not built to carry body weight, and leaning on them does not change the rated limit of the treadmill.
A patient is about to receive regadenoson for a pharmacologic stress test. Which statement by the EKG technician correctly prepares her for what she may feel?
A'Flushing or chest pressure is common and worth reporting to us.'
A is the keyed choice. Flushing or chest pressure is a common, short-lived effect of regadenoson, and the team wants to hear about it when it happens.
B'Most people feel no flushing or pressure at all.'
B goes wrong here. Most patients do feel something, and telling them otherwise leaves them frightened when the flushing or pressure comes.
C'Any chest pressure means we stop the test right away.'
C goes wrong here. Chest pressure is a common, expected effect of this drug; the team watches the EKG and the patient and decides, it is not an automatic stop.
D'You will likely feel drowsy and slow for the day.'
D goes wrong here. Regadenoson is not a sedative and its effects pass within minutes, so a day of drowsiness is not what to expect.
A 12-lead order for a patient with chest pain says 'compare with prior.' Before sending the new tracing, what should the EKG technician do?
AAsk the patient to bring the old printout at the next visit
A goes wrong here. Waiting for the patient to bring an old printout at the next visit is too late for chest pain, and the earlier tracing is already in the record.
BPull up the latest earlier tracing for the reader
B is the keyed choice. The order asks for a side-by-side comparison, so the technician finds the most recent earlier EKG and makes it visible to the reader.
CSend the new tracing alone and let the reader search
C goes wrong here. Sending the new tracing alone ignores the order to set up the comparison and risks a change from baseline being missed.
DCopy the old tracing's computer interpretation onto the new one
D goes wrong here. An old interpretation describes an old tracing; copying it onto a new EKG puts a false statement in the record.
Right after an EKG, the patient asks for a paper copy of the tracing to take to their primary care physician. What is the most appropriate response by the technician?
ADirect the patient to the facility's release-of-information process
A is the keyed choice. Copies of the record go through the release process, which checks identity and logs the disclosure; the technician does not hand them out alone.
BPrint a second copy and give it to the patient now
B goes wrong here. A right to copies exists, but a technician printing one and handing it over now skips the identity check and the disclosure log of the release process.
CHand the patient the original printout to take along
C goes wrong here. The original belongs in the facility's record; giving it away leaves the chart without the tracing.
DHave the patient sign a blank release form first, then hand it over
D goes wrong here. A blank form authorizes nothing specific, and the technician is still not the person who releases records.
To place V5, an EKG technician must find the anterior axillary line. Where does this line run?
AStraight down from the front fold of the armpit
A is the keyed choice. The anterior axillary line drops straight down from the front fold of the armpit, between the midclavicular and midaxillary lines.
BStraight down from mid-clavicle
B goes wrong here. Straight down from mid-clavicle is the midclavicular line, which lies closer to the sternum.
CStraight down from the back fold of the armpit
C goes wrong here. The back fold of the armpit marks the posterior axillary line, further toward the back.
DStraight down from the center of the armpit
D goes wrong here. The center of the armpit marks the midaxillary line, which lies behind the anterior one.
A patient with a pacemaker generator under the left clavicle needs 3-lead telemetry. Where should the technician place the black electrode?
AOmitted, with monitoring done from two electrodes
A goes wrong here. Three-lead monitoring needs all three electrodes; dropping one leaves no usable lead.
BDirectly over the generator for a firm hold
B goes wrong here. Over the generator the tracing picks up device noise and the skin over the pocket should be left alone.
CBelow the right clavicle, in place of the white
C goes wrong here. Swapping it into the white electrode's spot reverses the leads and distorts the tracing.
DNear its usual site, but not over the generator
D is the keyed choice. Near its usual site the lead still reads normally, and keeping it off the generator avoids device noise and the skin over the pocket.
A provider orders serial 12-leads every few hours on a patient with chest pain. What helps make the tracings comparable?
AShift the chest electrodes a little each time
A goes wrong here. Even small shifts change the waves in the chest leads and can look like a real change.
BRemove the electrodes and find the sites by eye
B goes wrong here. Removing the electrodes and finding the sites by eye each time is how chest leads drift between tracings.
CRecord each repeat in a different body position
C goes wrong here. Body position alters the EKG, so repeats are taken in the same position to stay comparable.
DMark the sites so repeats use the same spots
D is the keyed choice. Marking the sites means every repeat uses the same spots, so a change between tracings comes from the heart, not from moved electrodes.
After a 12-lead is recorded, the EKG cart shows a 'transmission failed' message when the technician sends it to the EHR. What should the technician do?
AHand the printout to the patient to deliver
A goes wrong here. Handing the printout to the patient skips the chart; the patient is not the delivery route for a tracing.
BAssume it will go through later without help
B goes wrong here. A failed send does not fix itself reliably; without a check the provider is left without the tracing.
CDelete the tracing from the cart and record a new one
C goes wrong here. The tracing is valid; deleting it and repeating the test wastes time when the problem is the transmission.
DRetry and confirm it appears in the chart
D is the keyed choice. Retrying the send and confirming the tracing appears in the chart is the only way to know the provider can see it.
During stage 2 of a treadmill test, a patient keeps turning to look at the monitor and has drifted toward the back of the belt, although he is keeping pace and feels well. What should the technician do?
APress the emergency stop button before he can fall
A goes wrong here. He is keeping pace and feels well; an emergency stop is for a real emergency and can itself make him stumble.
BTell him to grip the handrail firmly
B goes wrong here. A firm grip on the rail does nothing about what pulls him backward, which is turning to watch the monitor.
CCue him to face ahead while walking up front
C is the keyed choice. Looking back and drifting to the rear of the belt is a fall risk, and a simple cue to face forward fixes it while the test goes on.
DTurn the monitor so he can watch it safely
D goes wrong here. Watching the monitor is what pulls his head around; turning it toward him invites more of the same.
An elderly patient with severe senile purpura requires a diagnostic 12-lead EKG. How should the technician modify the standard skin preparation protocol for this patient?
AShave all fine body hair using a disposable safety razor
A goes wrong here. A razor on fragile skin can cut it; hair is clipped only where it truly stops contact.
BClean the skin gently but avoid vigorous mechanical abrading
B is the keyed choice. Fragile, easily bruised skin is cleaned gently, and the usual abrasion is skipped so the skin does not tear.
CApply a liberal amount of isopropyl alcohol and rub the skin firmly
C goes wrong here. Firm rubbing with alcohol is exactly the friction this skin cannot take.
DPlace the electrodes over the patient's lightweight cotton clothing
D goes wrong here. Electrodes need direct skin contact; cloth blocks the signal however thin it is.
The machine's printed statement on a resting 12-lead reads 'atrial fibrillation,' but the technician sees an upright P wave before every narrow complex at a steady 72/min. What should the technician do?
AKeep the computer statement and flag the mismatch
A is the keyed choice. The computer statement stays in the record for the reader to judge; the technician flags that a P wave sits before every complex, which does not fit the printed statement.
BDelete the statement and type 'normal sinus rhythm'
B goes wrong here. Deleting the statement and typing a rhythm name is interpreting the tracing, which belongs to the reader, not the technician.
CTell the patient the machine reading was wrong
C goes wrong here. Telling the patient anything about the reading goes beyond the technician's role and can alarm or mislead them.
DRepeat the tracing until the statement changes
D goes wrong here. Repeating the tracing until the statement changes hides the disagreement instead of reporting it.
While checking a resting tracing before it goes to the reader, a technician lays calipers across the QRS complexes in lead V1 and finds they span 3.5 small boxes at standard paper speed. What duration should be noted?
A350 ms, which is normal
A goes wrong here. 350 ms comes from treating each small box as 100 ms, and no QRS that long would be called normal.
B140 ms, which is wide
B is the keyed choice. Each small box at 25 mm/s is 40 ms, so 3.5 boxes is 140 ms, longer than the 120 ms upper limit for a narrow QRS.
C70 ms, which is short
C goes wrong here. 70 ms counts each small box as 20 ms, half its real value, so the QRS looks short when it is not.
D100 ms, which is normal
D goes wrong here. 100 ms would be 2.5 small boxes; the count here is 3.5.
Before an exercise stress test, the technician sees a first-degree AV block on the baseline 12-lead of a patient with no symptoms. What should the technician do before the treadmill starts?
AMove the chest electrodes to get a clearer PR
A goes wrong here. The PR interval is a conduction finding; moving electrodes does not change it and makes the tracing non-standard.
BNote it and confirm the protocol with the provider
B is the keyed choice. A baseline abnormality is recorded and brought to the supervising provider, who decides whether the planned protocol stands.
CStart the standard protocol and skip telling the physician
C goes wrong here. Starting without telling the supervising physician leaves a baseline finding unreported before the heart is stressed.
DGive a nitroglycerin tablet under the tongue to shorten the PR
D goes wrong here. Giving nitroglycerin is outside the technician's role, and it is not a treatment for a long PR interval.
A patient's rhythm strip shows sinus beats with P-to-P intervals of 0.80 s. Then the baseline stays flat for 2.6 s, with no P wave and no ventricular complex, before sinus beats resume. What should the technician note for the reader?
AThe usual pause after an early beat
A goes wrong here. A compensatory pause follows a premature beat, and no early beat comes before this gap.
BLead-off artifact in a sinus rhythm
B goes wrong here. Sinus beats resume on the same lead with no reconnection, so the lead did not come off, and a pause this long always needs a comment.
CA blocked P wave, with no complex after it
C goes wrong here. A blocked beat leaves a P wave standing alone; here the P wave is missing too, so the sinus node did not fire at all.
DA sinus pause, recorded with its length
D is the keyed choice. A flat stretch with no P wave and no complex between normal sinus beats is a sinus pause, and its length in seconds goes in the note.
After you answer, a note opens under every choice: what makes the keyed answer correct, plus the flaw in every other option. Open them on the cards you answered correctly too; a guess that happened to land earns the same point as real knowledge.
Misses on these cards tend to fall into three kinds:
A landmark or number you did not know, such as an electrode site or a normal interval. Drill those from the study guide.
A stem read in a hurry, where a qualifier such as FIRST or BEFORE changed what was asked.
A choice that steps outside the technician's role. The scope part of the study guide covers where that line runs.
Each card's domain label tells you which section of the study guide to reopen.
How this set differs from an NHA exam form
This page is practice, not a preview. None of its questions is taken from NHA's own practice tests or study guide. Three differences from the real sitting:
The real form holds 120 questions, with 120 minutes to finish them, and 20 are trial questions that count for nothing and carry no marker.
Scores are scaled, and a pass is 390. Percentages from practice do not translate into that scale.
NHA has posted a newer plan that moves a few questions from acquisition to the other two domains, and has not set a date for the switch.
A score on 30 cards is too small to predict a result. Use it to see which domain needs time. Format and scoring are covered in full on exam facts.
Practice material from NHA
NHA posts its CET test plan free and sells online practice tests and an interactive study guide. None of it is required for registration; prices are on the registration page.
Taken fromCET test plan 2017 1CET test plan 2026 3NHA handbook 2026 4NHA pass rates 2025 5
After the last card
The patient care technician practice set
About this EKG practice set
Is any question here lifted from NHA's real exam?
No. NHA does not release its exam questions, and none of these comes from NHA's paid practice tests. They are practice questions sorted by the domains of NHA's current test plan.
Can this set tell me when to book the NHA EKG exam?
No. A short set cannot predict a scaled score, and NHA's pass mark of 390 is not a percentage. Look at which domain your misses come from and study that part first.
Does this set follow the test plan NHA uses now?
Yes, the 2017 plan. NHA keeps it until the next version launches, and that launch has no date yet.
Taken fromNHA handbook 2026 4NHA pass rates 2025 5
Sources
Every document below was held against its figures on Nov 17, 2026.