NHA CET · study guide · 2017 test plan, 2026 plan noted

NHA EKG study guide: the three CET domains in turn

This NHA EKG study guide works from the plan the Certified EKG Technician exam uses now, the one from NHA's 2017 job analysis. Each domain gets a section: what the tasks are, what questions about them usually test, and where candidates slip. EKG Acquisition has the longest section, since it holds 44 of the 100 scored questions. Heart anatomy, emergencies and CPR have no domain of their own; they appear inside the sections where questions use them. Worked questions close the page.

Papers behind this page

6 more documents in the list at the end

Read most recently on

Questions 100 + 20 scored + unscored trial items
Time 2 h computer multiple choice
Pass mark 390 scaled, 200–500
Fee $134 paid when you apply
Pass rate 70.45% all attempts, 2025
Next test plan expected winter 2027/28 2026 test plan
On this page 8 sections
  1. Domain 1. Safety, Compliance, and Coordinated Patient Care, 32 questions
  2. Domain 2. EKG Acquisition, 44 questions
  3. Domain 3. EKG Analysis and Interpretation, 24 questions
  4. The 2026 plan NHA has posted, and how to use it now
  5. Check yourself across the three domains 12
  6. Practice set, exam rules and booking
  7. Studying for the NHA EKG exam 4
  8. Sources

How the 2017 plan, in force now, spreads the 100 scored questions.

Test plan in use

2017 test plan · counts of 100 scored questions CET test plan 2017 1 CET news 2026 2

expected winter 2027/28 NHA has posted the next plan but set no launch day

Posted, not yet in use

2026 test plan CET test plan 2026 3 CET crosswalk 2017–2026 4
  • Safety, Compliance, and Coordinated Patient Care 32 → 34 posted
  • EKG Acquisition 44 → 40 posted
  • EKG Analysis and Interpretation 24 → 26 posted
Domain Questions Topics listed
1. Safety, Compliance, and Coordinated Patient Care 32 HIPAA, infection control, scope of practice and ethics, communication with patients and the care team, vital signs, instructions for stress tests and ambulatory monitors, entering data in the EHR, and signs of cardiopulmonary compromise.
2. EKG Acquisition 44 Equipment care, machine speed and gain, skin preparation, patient positioning, electrode and lead placement for 12-lead, ambulatory, stress and telemetry recordings and special cases, checking every lead, resolving artifacts, mounting the tracing, and support during stress tests.
3. EKG Analysis and Interpretation 24 Heart rate and rhythm regularity, intervals and waveforms, arrhythmias including heart blocks, pacemaker spikes, ischemia, injury and infarction, and the right action for life-threatening rhythms.

Domain 1. Safety, Compliance, and Coordinated Patient Care, 32 questions

This domain is about the patient around the tracing. The plan lists privacy of health information, infection control, scope of practice and ethics, communication with patients and the care team, vital signs, instructions before stress tests and ambulatory monitors, entering data in the electronic record, and recognizing signs that the heart or lungs are in trouble.

Questions here are set in cardiac testing rather than general care. Expect a patient on a treadmill, a patient going home with a monitor, a telemetry screen that needs watching. Typical tasks:

  • Before a stress test, tell the patient what to wear and what to expect.
  • Before a monitor goes home, explain the symptom diary, the event button if there is one, and how to keep the device dry and attached.
  • Adjust the explanation to the person: a child, a patient with hearing loss, someone who does not share your language, someone with dementia.
  • Know the warning signs that end your task and start a call for help: chest pain, sudden shortness of breath, heavy sweating, confusion, fainting.
The technician reports; the provider explains results

When a patient asks whether the tracing looks bad, the safe answer refers the question to the provider. Saying it looks fine is as far outside the role as saying it looks dangerous.

Identity before electrodes

Confirm who the patient is with two identifiers before you prepare the skin, not after the tracing prints. A perfect 12-lead filed under the wrong name is worse than none.

Taken from CET test plan 2017 1 CET news 2026 2

Domain 2. EKG Acquisition, 44 questions

Nearly half the score, and the part that separates this exam from a rhythm-reading course. The plan covers equipment care, machine settings, skin preparation, positioning, electrode placement for 12-lead, ambulatory, stress and telemetry recordings, special cases, checking that every lead recorded, fixing artifacts, mounting the tracing, and supporting the patient during a stress test.

Settings first. Standard speed is 25 mm per second and standard gain 10 mm per mV; a tracing at any other value has to say so, or it will be misread. Position the patient flat on the back, arms resting by the body and legs uncrossed; raise the backrest only for someone who cannot lie flat, and note it.

Chest leads, from landmarks you can feel:

  • V1 goes in the fourth intercostal space at the right edge of the breastbone; V2 takes the same space at the left edge.
  • V4 goes in the fifth intercostal space on the midclavicular line, and V3 halfway between V2 and V4.
  • V5 and V6 continue level with V4, on the anterior and midaxillary lines.

To find the fourth space, start at the sternal angle, the ridge where the handle of the sternum meets its body. The second rib joins there; the space under it is the second, and you count down two more. On a patient with large breasts, place V4 to V6 beneath the breast tissue, not over it.

For a treadmill test, the limb electrodes move onto the torso, below the clavicles and on the lower abdomen or flanks. A Holter or event recorder uses its own sites, chosen over bone; telemetry uses three or five electrodes in set positions. Special cases include amputations, a pacemaker generator under the skin, children, and right-sided or posterior leads ordered by the provider. Whatever you change, note it on the tracing.

Counting from the clavicle lands V1 and V2 high

Starting the count at the clavicle instead of the sternal angle tends to put both electrodes a space or two up. The tracing then looks like it has lost R waves across the chest, a pattern the reader may take for an old infarction.

Reversed arm wires turn lead I upside down

Swap the right and left arm electrodes and lead I comes out inverted, both P and QRS negative; aVR and aVL exchange tracings, and so do II and III. It can look like a heart on the wrong side. Check the limb clips before you send the tracing.

Artifacts are asked as a chain: what you see on the tracing, what causes it, what you do about it.

  • Somatic tremor: an irregular, jittery baseline from muscle activity. The usual causes are a cold or tense patient, shivering or a tremor disorder. The fix is a blanket, a pillow under the arms and a minute for the patient to settle.
  • 60-cycle interference: a thick, regular fuzz along the whole baseline. It comes from electrical devices nearby or a cable lying across a power cord. Unplug what you can, untangle and reroute the cables, and keep the bed away from the wall.
  • Wandering baseline: the line drifts up and down. Look for lotion or sweat on the skin, a drying electrode, or deep breathing. Clean and dry the site, use fresh electrodes, and ask the patient to breathe quietly.
  • A straight or broken line in one lead only: a loose electrode or a damaged wire. Find the lead that shares it and reattach or replace.
A stress test stops on symptoms, not on the schedule

During exercise you watch the patient and the monitor together. Chest pain that grows, dizziness or near fainting, pale and clammy skin, a falling blood pressure, a sustained fast wide-complex rhythm, a monitor you can no longer read, or the patient asking to stop all mean you tell the supervising provider at once. The provider decides how the test ends; you do not push on to the next stage.

Taken from CET test plan 2017 1 CET news 2026 2

Domain 3. EKG Analysis and Interpretation, 24 questions

This domain asks you to read enough of a tracing to act: rate and regularity, intervals and waveforms, arrhythmias including heart blocks, pacemaker spikes, signs of ischemia, injury and infarction, and the right response to a rhythm that threatens life. It is a technician's reading, aimed at recognizing and reporting, not a cardiologist's.

The conduction path underlies all of it: the SA node fires, the impulse crosses the atria to the AV node, then runs down the bundle of His, the bundle branches and the Purkinje fibers. Each wave on the tracing marks one part of that trip.

Box arithmetic first. At 25 mm per second, one small box is 0.04 seconds and one large box, five small ones, is 0.20 seconds.

Heart rate, three ways:

  • Six seconds of tracing, thirty large boxes, holds a sample of beats: the QRS count in that window times ten is the rate per minute. Use it whenever the rhythm is irregular.
  • When beats are evenly spaced, count the large boxes in one R-to-R gap and take 300 over that count, or 1500 over the small boxes for a finer figure.
  • For a stress test target, the common estimate of maximum heart rate is 220 minus age, and the protocol sets the share of it to reach.

Normal adult values to know: PR interval 0.12 to 0.20 seconds, QRS under 0.12 seconds, and a QT that shortens as the rate rises. Rhythms you should be able to name from a description include sinus rhythm, bradycardia and tachycardia, atrial fibrillation (no clear P waves, irregularly irregular) and flutter (sawtooth waves), PVCs, ventricular tachycardia and fibrillation, asystole, and the four heart blocks, told apart by how the PR interval behaves from beat to beat and whether any P wave goes unanswered.

On the injury side, ST elevation, ST depression, inverted T waves and new Q waves are reported, not diagnosed.

Check the person, then the monitor

A chaotic line or a flat line on the monitor is first checked against the person. A patient who is talking is not in ventricular fibrillation or asystole, so look for a loose lead, then confirm a flat line in a second lead with the gain turned up. A patient who is unresponsive needs help called and CPR started without waiting for a better tracing.

The large-box shortcut fails on irregular rhythms

Dividing 300 or 1500 by one R-to-R gap gives the rate of that one beat. On atrial fibrillation or frequent ectopy the answer changes from gap to gap, so use the 6-second count.

Taken from CET test plan 2017 1 CET news 2026 2

expected

The 2026 plan NHA has posted, and how to use it now

NHA has published a test plan from its 2026 job analysis for the next exam version. The launch is announced for a season, winter 2027/28, without a day, and until then the forms follow the 2017 plan above. In the posted plan:

  • Safety, Compliance, and Coordinated Patient Care moves from 32 to 34 questions.
  • EKG Acquisition moves from 44 to 40.
  • EKG Analysis and Interpretation moves from 24 to 26.
  • The plan adds 7 tasks, most of them in patient care: identifying the patient, consent, a general health check, reporting warning signs, body mechanics, privacy during undressing, and electronic transfer of the tracing with two identifiers.

Everything this guide covers stays in the newer plan. If you study now and test after the launch, add those tasks; nothing has to be unlearned.

Taken from CET test plan 2017 1 CET news 2026 2 CET test plan 2026 3 CET crosswalk 2017–2026 4

Check yourself across the three domains

Answered 0 of 12 · right 0

Safety & patient care · 32% 1 of 12 Nuclear —

An EKG technician is preparing a 32-year-old woman for a nuclear stress test. Which question is MOST important to ask before the radioactive tracer is given?

Pick a letter to lock it in; then each option shows its own reasoning.

  1. 'When did you last have an alcoholic drink?'
    A goes wrong here. Alcohol is not a screening point for the tracer; the drinks that matter before some stress tests are caffeinated ones.
  2. 'Are you pregnant or breastfeeding?'
    B is the keyed choice. Pregnancy or breastfeeding matters because the radiotracer would expose a fetus or nursing infant to radiation, so the answer must reach the provider ahead of the dose.
  3. 'Are you allergic to iodine or shellfish?'
    C goes wrong here. Nuclear stress tracers contain no iodine, and a shellfish allergy is not a contrast allergy in any case; this is the CT-dye question.
  4. 'Do you have any metal implants?'
    D goes wrong here. Metal implants are the MRI safety question; a gamma camera and a radiotracer are not affected by them in that way.
Safety & patient care · 32% 2 of 12 —

Before placing electrodes for a morning pharmacologic stress test, which check should the technician make first?

  1. Confirm the resting rhythm matches older records
    A goes wrong here. A changed resting rhythm is something to report, but matching old records is not a condition for starting, and it is not a safety check.
  2. Set the treadmill grade and draw up the stress drug
    B goes wrong here. Preparing the stress drug is the job of the nurse or provider, not the EKG technician, and the treadmill setting is not the first safety step.
  3. Verify insurance and print the telemetry log
    C goes wrong here. Insurance is handled at registration and a telemetry log has no role here; neither protects the patient during the drug infusion.
  4. Confirm signed consent and a ready crash cart
    D is the keyed choice. A drug-induced stress test needs documented informed consent, and the emergency cart must be stocked and ready before the drug is given.
Safety & patient care · 32% 3 of 12 Stress —

Before an exercise stress test, the EKG technician checks the patient's level of consciousness, breathing, and skin color. What is the main purpose of this check?

  1. To establish a baseline for comparison during the procedure
    A is the keyed choice. A baseline of how alert the patient is, how they breathe and what color the skin is lets the team spot a change once the treadmill is moving.
  2. To verify identity and confirm the medical history
    B goes wrong here. Identity is checked with two identifiers and history comes from the chart; looking at skin color confirms neither.
  3. To set the target heart rate for the protocol
    C goes wrong here. The target heart rate comes from age (and the provider's order), not from a look at consciousness and skin.
  4. To find the correct sites for the chest electrodes
    D goes wrong here. Chest electrode sites are found by bony landmarks, not by the patient's color or breathing.
Safety & patient care · 32% 4 of 12 —

The evening before a treadmill stress test, a patient calls to ask how to get ready. Which instruction should the EKG technician give?

  1. Eat a large meal just before you arrive
    A goes wrong here. A large meal right before exercise is discouraged; patients are asked not to eat for at least three hours before the test.
  2. Have a cigarette just before you come in
    B goes wrong here. Smoking right before an exercise test raises heart rate and blood pressure and can bring on symptoms; patients are asked not to smoke for a few hours beforehand.
  3. Wear walking shoes with a two-piece outfit
    C is the keyed choice. Walking shoes keep the footing safe on a moving belt, and a two-piece outfit lets the chest be prepared without a full change of clothes.
  4. Wear a snug one-piece outfit for the test
    D goes wrong here. A snug one-piece outfit has to come off entirely for the chest electrodes and restricts movement on the treadmill.
Acquisition · 44% 5 of 12 —

A technician notices that tracings from one EKG machine have become faint and streaky although settings and paper are correct. What maintenance is MOST appropriate?

  1. Use a faster paper speed on this machine
    A goes wrong here. Paper speed stretches the tracing in time and changes every measurement; it does nothing for a dirty print head.
  2. Clean the print head as the manual directs
    B is the keyed choice. Residue on a thermal print head gives faint or streaked printing even when settings and paper are right; the manual gives the cleaning method.
  3. Increase the gain to darken the print
    C goes wrong here. Gain changes how tall the waves are drawn, not how dark the ink-free thermal print is; it would distort the tracing instead.
  4. Switch to double standard for every patient
    D goes wrong here. Double standard is a gain setting for small complexes, and using it routinely would mislabel every tracing's voltage.
Acquisition · 44% 6 of 12 —

A provider orders a small adhesive rhythm monitor with no lead wires that the patient wears continuously for up to 2 weeks. Which type of device is this?

  1. A telemetry transmitter
    A goes wrong here. Telemetry sends the rhythm to a central station while the patient is in the hospital and uses lead wires to several electrodes.
  2. An implantable loop recorder
    B goes wrong here. A loop recorder of this kind is placed under the skin in a procedure; it is not an adhesive device on the surface.
  3. A long-term patch monitor
    C is the keyed choice. A patch monitor sticks to the chest as one unit with no lead wires and can record continuously for up to about two weeks.
  4. A standard Holter monitor
    D goes wrong here. A Holter has lead wires running to a recorder and is usually worn for 24 to 48 hours, not up to two weeks.
Acquisition · 44% 7 of 12 —

A patient has brief spells of dizziness that pass within seconds. Why might an external loop recorder be chosen instead of a post-event recorder?

  1. It needs no electrodes attached to the skin
    A goes wrong here. An external loop recorder does use skin electrodes; only an implanted loop recorder works without them.
  2. It can be worn for several years at a time
    B goes wrong here. Years of recording describe an implanted loop recorder; an external one is worn for weeks.
  3. It sends every heartbeat to the provider live
    C goes wrong here. Live beat-by-beat transmission is mobile cardiac telemetry, a different device; a loop recorder stores events.
  4. It saves the rhythm before the button press
    D is the keyed choice. A loop recorder keeps a rolling memory, so a press after a few-second spell still saves the rhythm from the moments before it.
Analysis · 24% 8 of 12 AV block —

On a resting rhythm strip, the PR intervals of consecutive beats measure 0.16 s, 0.22 s and 0.28 s; the next P wave stands alone with no ventricular complex after it, and the cycle then starts over at 0.16 s. Which finding should the technician flag for the reader?

  1. First-degree AV block only
    A goes wrong here. First-degree block conducts every P wave; a P wave with no complex after it rules this out.
  2. Third-degree (complete) AV block
    B goes wrong here. In complete block P waves and complexes are unrelated; here the PR grows in a fixed pattern and resets, so conduction is still linked.
  3. Second-degree AV block, type I (Wenckebach)
    C is the keyed choice. The PR gets longer beat by beat until one P wave is not conducted, and then the cycle starts over; that is type I.
  4. Second-degree AV block, type II (Mobitz II)
    D goes wrong here. Type II drops a beat without warning: the PR stays the same before the blocked P wave, which is not what these numbers show.
Analysis · 24% 9 of 12 —

A technician sees a steady rate of 50/min, narrow ventricular complexes, and an inverted P wave in lead II sitting right against each complex. Which pacemaker site should the technician suspect when flagging the strip?

  1. The sinus node
    A goes wrong here. A sinus impulse gives an upright P wave in lead II at a normal PR distance before the complex.
  2. The AV junction
    B is the keyed choice. An inverted P wave in lead II right next to a narrow complex at about 50/min points to an impulse starting in the AV junction.
  3. A ventricular site
    C goes wrong here. A ventricular pacemaker gives wide complexes, usually at 20 to 40/min, not narrow ones at 50.
  4. The bundle branches
    D goes wrong here. An impulse arising in a bundle branch spreads abnormally through the ventricles and gives a wide complex, not a narrow one.
Analysis · 24% 10 of 12 —

A student technician sets the calipers from where the P wave ends to where the next ventricular complex begins. Which span is that?

  1. The ST segment
    A goes wrong here. The ST segment comes after the QRS, from the J point to the start of the T wave.
  2. The QT interval
    B goes wrong here. The QT interval runs from the start of the QRS to the end of the T wave, a different span entirely.
  3. The PR interval
    C goes wrong here. The PR interval includes the P wave itself; starting the calipers at the end of the P wave leaves that part out.
  4. The PR segment
    D is the keyed choice. From the end of the P wave to the start of the QRS is the PR segment; the PR interval starts earlier, at the beginning of the P wave.
Analysis · 24% 11 of 12 —

In lead II, the clearest PR interval spans 4.5 small boxes at a paper speed of 25 mm/s. What is the PR interval, and is it normal?

  1. 180 ms, within the normal range
    A is the keyed choice. 4.5 small boxes at 40 ms each is 180 ms, inside the normal PR range of 120 to 200 ms.
  2. 225 ms, a first-degree AV block
    B goes wrong here. 225 ms would need about 5.6 small boxes; this reading overcounts the interval.
  3. 90 ms, shorter than normal
    C goes wrong here. 90 ms counts each small box as 20 ms; at 25 mm/s a small box is 40 ms, so the PR is not short.
  4. 180 ms, a first-degree AV block
    D goes wrong here. The arithmetic is right but the cutoff is wrong: first-degree block begins above 200 ms, not at 180.
Acquisition · 44% 12 of 12 —

Paper jams in the EKG machine in the middle of a tracing. What should the EKG technician do?

  1. Stop, clear the jam, reload, then repeat the tracing
    A is the keyed choice. A jam ruins the record, so the technician stops, clears and reloads the paper, then records a new full tracing.
  2. Restart the machine and let it feed the jammed paper through
    B goes wrong here. Restarting and forcing the jammed paper through can tear it and damage the mechanism.
  3. Finish the tracing on the jammed paper, then trim it
    C goes wrong here. Finishing on jammed paper gives a distorted tracing with parts of leads lost; trimming it later cannot fix that.
  4. Pull the paper out gently while the machine keeps printing
    D goes wrong here. Pulling paper while the machine runs gives a stretched, unreliable tracing and risks the mechanism.

Practice set, exam rules and booking

Studying for the NHA EKG exam

Which part of the NHA EKG exam should I study first?

EKG Acquisition, which carries 44 of the 100 scored questions. Electrode landmarks, machine settings and artifacts are quick to learn and come up often.

Do I have to interpret EKGs like a cardiologist?

No. The exam expects you to measure, recognize dangerous rhythms and report them; diagnosis stays with the provider.

Should I study from the 2026 test plan instead?

Not yet. The exam follows the 2017 plan until NHA launches the new version, and no date is set. The newer plan keeps the same topics and adds 7 tasks, most of them in patient care.

What share of the NHA EKG exam is rhythm interpretation?

EKG Analysis and Interpretation is 24 scored questions, but rhythm knowledge also shows up in patient care, where you respond to a dangerous rhythm, and in acquisition, where you tell artifact from a real rhythm.

Taken from CET test plan 2017 1 CET news 2026 2 CET test plan 2026 3 CET crosswalk 2017–2026 4

Sources

Every document below was held against its figures on Nov 17, 2026.

  1. 1 NHA CET test plan from the 2017 job analysis, the plan in use now (PDF) info.nhanow.com
  2. 2 NHA News Center, September 2026: the updated CET exam and study materials info.nhanow.com
  3. 3 NHA CET test plan from the 2026 job analysis, for the next exam version (PDF) info.nhanow.com
  4. 4 NHA CET crosswalk of 2017 tasks to 2026 tasks (PDF) info.nhanow.com
  5. 5 NHA handbook for candidates, updated 10/05/2026 (PDF) nhanow.com
  6. 6 NHA 2025 pass rates by exam (PDF, revised 01/09/26) nhanow.com
  7. 7 NHA Store: CET exam application and prep (prices read November 17, 2026) store.nhanow.com
  8. 8 NHA 2024 pass rates by exam (PDF, revised 1/8/25) nhanow.com
  9. 9 NHA: CET certification overview and eligibility nhanow.com
  10. 10 NHA: accreditation, job task analysis summaries and pass-rate files nhanow.com